Skip to content

nl_liander_stations

Liander Open Data Elektra: Hoogspanningsstation (layer 641)

Published by Liander / NL / Monthly

Grantedcommercial_use_with_attributionDegraded

Liander's HV/MV substations (onderstations), switching stations and regulating stations: name, function, voltage levels, Liander's asset ID and location. A station register; it publishes no capacity.

Liander Open Data Elektra: Hoogspanningsstation (layer 641) on a map

The 348 located assets in this publication, coloured by the spare capacity Liander publishes for each today. Click a point for its figure.

The map of Europe →

Loading the map…

What is withheld, and why

Nothing is withheld. Values are served with the attribution the licence asks for: Liander 2026, Liander Open Data Elektra, CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Liander behoudt zijn intellectuele eigendomsrechten (zoals het databankenrecht).. Keep it with any figure you show.

Two statements, both permissive: the ArcGIS item's licence field is CC BY 4.0, and Liander's open-data disclaimer allows copying, distribution and reuse on condition of the formula 'Liander' + year of publication. The attribution carries both. The same disclaimer forbids links to Liander's sites without prior written permission, so no deep link is stored; landing_url is the one link shown. The item's snippet says the HV network in the service is partly Liander's and partly TenneT's: the stations are published by Liander as Liander's register and attributed to Liander, as published.

Licence and rights evidence

Attribution
Liander 2026, Liander Open Data Elektra, CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Liander behoudt zijn intellectuele eigendomsrechten (zoals het databankenrecht).required
Technical access
Yes
Commercial use
Yes
May be cached
Yes
May be redistributed
Yes
Derived data allowed
Yes

Evidence

Methodology

1 version(s)

Liander station register (locations, functions and voltage levels)

nl_liander_stations_register · vLiander Open Data Elektra, layer 641

Liander's own register of its HV/MV substations, switching and regulating stations as published in its open-data GIS: a point, a name, a function and the voltage levels per station. No capacity is stated.

Capacity basis
operator published
Network state
unknown
Binding
No
Additive across assets
No. Do not sum these figures.
The method accounts for
reserved: not stated · allocated: not stated · pre-reserved: not stated · pending requests: not stated
Comparability class
nl_liander_station_register

The operator’s own caveats

  • Liander's open-data disclaimer: Liander and its service providers 'aanvaarden geen enkele aansprakelijkheid' for damage arising from the use of the data.

How the publication maps to the model

availability types
[]
binding
false
directions
["unknown"]
firmness
[]
geometry precision
exact
includes reserved projects
null
non additive
true
notes
["Asset-only: no capacity values. It gives Liander's stations a location (points from Liander's asset GIS, requested with outSR=4326 so the service projects from its native RD New; never re-projected by us), their voltage levels (SPANNINGSNIVEAUS '150kV/50kV/10kV') and Liander's own asset ID, carried as the identifier liander_asset_id.","Layer 641 is not only stations: of 719 features (2026-09-25), 173 Onderstation, 2 Onderstation GVB, 102 Schakelstation and 71 Regelstation are stations and become assets; 158 Manometer, 121 Aarding- en Manometer, 73 Aarding and 19 Opstijgpunt are accessories of the HV cable system and are skipped and counted. A FUNCTIE the parser has not seen is a rejection.","The station points are not the geometry of the national map's supply areas: those are published as postcode sets (nl_nbnl_postcodes). A supply area and a station are related, never merged."]
spatial scope
substation
technologies
[]
units
["count"]

Query this source